EME20 Middle Ear Analyzer
$0.00
Probe tone: 226Hz (85dB SPL)
Tympanogram: 0.2cm³~5cm³
Tympanum compensation diagram: 0cm³~2cm³
EME20 Middle Ear Analyzer
Feature:
1. A device for tuning and static pressure for middle ear, suitable for the diagnosis of iliac disease diagnosis.
2. The unique manual and automatic control of the air pump is used to provide a variety of pressure range and pump speed selection. Medical staff can set the air pressure range and pump speed as needed to perform drum compression tests with automatic or manual air pump control.
Superiority:
1. Tympanogram test、Complete/perforated eustachian tube functional test
2. Sound reflection test、Acoustic reflection attenuation test、Acoustic reflects latency test
3. Quick test:Two user-defined quick tests can be generated,with the test time ≤60s
4. With the “Live View”feature,you can see a panoramic view of the test in progress on your computer screen,
5. Color touch screen +touch button with working mode
Technical Parameters | |
Probe tone | 226Hz (85dB SPL) |
678Hz、 800Hz、1000Hz (Optional) | |
Measuring range | Tympanogram: 0.2cm³~5cm³ |
Tympanum compensation diagram: 0cm³~2cm³ | |
Total hamornical distortion | Less-than 1 % 【226Hz (85dB SPL)】 |
Stimulation level reach 110dB, no more than ±5%(Probe type earphone) | |
Auto test | Quick testA、B (Tympanogram & Acoustic reflection sequence) |
Pressure range | -600 to +400 daPa |
Pump pressure velocity | 15、50、100、200、300、400、600 daPa/s |
Automatic range | 200~600 daPa/sec |
Pump control | Auto and manual |
Tympanogram | Test mode:Acoustic admittance(Y), Acoustic susceptance(B), Acoustic conductance(G) |
Large pressure: -600~+400 daPa | |
Eustachian tube | Testing of intact tympanic membrane and Eustachian tube |
Testing of perforated tympanic memeranes and Eustachian tubes | |
Acoustic reflex | Test mode: Fixed strength, Automatic threshold , Increasing strength,Manual |
Maximum permissible error: No more than ± 1 % | |
Acoustic attenuation test | |
Acoustic refles latency test(ARLT) | |
Stimulus | Ipsilateral, contralateral |
Stimulation level 500Hz~2000Hz | |
Auditory sensation area 50dB~100dB | |
BBN (Broadband noise) | |
LPN (Lowpass noise) | |
HPN (High-pass noise) | |
Max sound intensity: Lpsilateral 110dB HL, Contralateral 120dB HL |
Chongqing vision star is a supplier of professional medical devices, including medical laboratory equipment, surgical equipment, ultrasound machines, radiology equipment, ophthalmology equipment, dental equipment, ENT equipment, obstetrics and gynecology equipment, neonatology equipment, rehabilitation room equipment, beauty equipment, hospital furniture, medical consumables and supplies. You can find a wide range of high quality devices that made in China for hospital or clinic. In the passed 20+ years, we have exported more than 150 countries, provided effective solutions for various types of medical system, and established long term cooperation with distributors and tenders in many countries. We sincerely support every customer with best products, prices, services, and warranty. For distributors and resellers, we can label your own logo on the devices if your order reaches MOQ. We can also help you to source more products that have not been listed on our website. Contact us to get more information.