Products

Contact Us

Sales Director: John Gao

Cellphone: +86-13618377608

Email: sales@hyvisionstar.com

Whatsapp: +8613618377608 (click to chat)

Wechat: hyvisionstar

Address: Chongqing 400030, China

LSL400 Multiparameter Simulator

$0.00

Model: LSL400

LSL400 Multiparameter Simulator is aportable device, features in small volume and light weight.
It can simulate accurately 12-lead ECG, Respiration,Temperature,2-channel IBP or 4-channel IBP.
And it can be tested in where the monitor isused.
CE Certified.

Quantity:

Purchase professional medical equipment for clinic, hospital, or become our distributor. Send an inquiry or contact us now.

Send Inquiry

Chat on WhatsApp: +8613618377608

LSL400 Multiparameter Simulator

Feature:

LSL400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration,Temperature,2-channel IBP or 4-channel IBP. And it can be tested in where the monitor is used.

Standard accessories:

9V/1A(CE) power adapter, an User manual, a packaging box,a plastic packaging.

Optional accessories:

a power adapter(15V/1A)(UL), a power adapter(15V/1A),a temperature cable,an IBP cable, a CD disk(including a case conversion software).

Function:

*Simulate 35 kinds of arrhythmia (including Atrial, Ventricular, Premature Beat and Conduction Defects) and pacemaker waveforms (including Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non Capture, Non Function).
*Simulate four-channel IBP data.
*Simulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three kinds of apnea data.
*Simulate four kinds of temperature data.
*Simulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency.
*Simulate standard ECG calibration, adult and pediatric ECG signal.
*ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG database and user-defined waveform data stored in TF card can be displayed by the simulator and exported to the equipments to be tested.
*Each waveform can be displayed by sliding the 3.5″ TFT touch screen, easy to operate.
*Power supply: rechargeable lithium battery or linear adapter, which reduces interference.
*Optional operation modes: keys and touch screen.

 

Technical Data:
ECG            
Conventional All leads have the same voltage with the II-lead as the reference
Amplitude 0.5,1.0,1.5 and 2.0mV
ECG Rate 0,15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320, 340and 350 BPM
ECG artifacts 50 and 60 Hz, muscle, baseline and breathing
The elevation of the ST segment +0.8 to -0.8 mV, the step is 0.1 mV
Arrhythmia  
Atrial Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat,Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
Ventricular Vent Fib (coarse), Vent Fib (fine),
PVCs 6/min, PVCs 12/min, PVCs 24/min,
Frequent Multifocal, Bigeminy,
Trigeminy, Paired PVCs, Run 5 PVCs, Run
11 PVCs, Vent Tachycardia, Asystole
Premature Beat Atrial PAC, Nodal PNC, PVC1 LV Focus,
PVC1 E LV Focus, Ron T LV Focus,PVC2 RV
Focus, PVC2 E RV Focus, R on T RV Focus,
Multifocal PVC
Conduction Defects First Degree Heart Block, Second Degree
Heart Block, Third Degree Heart Block,
Right Bundle Branch Block, Left Bundle
Branch Block.
Four IBP Channels  
Dynamic IBP(unit: mmHg)  
Channel 1 Artery 120/80
Radial 120/80
Left Ventricle 120/00
Right Ventricle 25/00
Channel 2 Artery 120/80
Radial 120/80
Left Ventricle 120/00
Right Atrium(CVP) 15/10
Right Ventricle 25/00
Pulmonary Artery 25/10
Pulmonary Wedge 10/2
Left Atrium 14/4
Channel 3 Artery 120/80
Radial 120/80
Left Ventricle 120/00
Right Atrium(CVP) 15/10
Right Ventricle 25/00
Pulmonary Artery 25/10
Pulmonary Wedge 10/2
Left Atrium 14/4
Channel 4  
Auto Swan-Ganz (every 15 seconds) RA(CVP), RV, PA, PAW (Pulmonary Wedge)
Man Swan-Ganz  press ENTER key to change every time
Static-Pressure Levels  
Channel 1 100,0, 80, 160, 240, 320 and 400mmHg
Channel 2 100,0, 50, 100, 150, 200 and 250mmHg
Channel 3 100,0, 20, 40, 60, 80 and 100mmHg
Channel 4 P4 tracks the static pressure levels of P3
Respiration  
Respiration Rate 0 (Apnea), 15, 20, 30, 40, 60, 80, 100,
120 and 150 R/MIN
Impedance 0.2, 0.5, 1.0and 3.00
Baseline impedance 500, 1000, 1500, 2000N
Apnea 12s, 22s,32s
Temperature  
Four temperature 0°C(32°F),24°C(75°F),37°C(98.6°F), 40°C(104°F)
Packing  
Dimension 18.86 cm(L)X 12.50 cm(W)X 4.32 cm(H)
Net weight about 1.4kg

Chongqing vision star is a supplier of professional medical devices, including medical laboratory equipment, surgical equipment, ultrasound machines, radiology equipment, ophthalmology equipment, dental equipment, ENT equipment, obstetrics and gynecology equipment, neonatology equipment, rehabilitation room equipment, beauty equipment, hospital furniture, medical consumables and supplies. You can find a wide range of high quality devices that made in China for hospital or clinic. In the passed 20+ years, we have exported more than 150 countries, provided effective solutions for various types of medical system, and established long term cooperation with distributors and tenders in many countries. We sincerely support every customer with best products, prices, services, and warranty. For distributors and resellers, we can label your own logo on the devices if your order reaches MOQ. We can also help you to source more products that have not been listed on our website. Contact us to get more information.