OPM200 Handheld Patient Monitor
$0.00
OPM200 Handheld Patient Monitor
Feature:
* Accurate measurement in 0.05% low Perfusion Index, the word leading production in the movement environment.
* Provide the parameter of PI(Perfusion Index 0.05%-20%).
* Accurate measurement in all kind of extreme environment measurement such as neonatal and shock patients.
* Easy operation by 4″ color TFT.
* Up to 100 users ID switch.
* Multiple vital signs measurement parameters for collocation optional:
3/5 Leads ECG, NIBP Spo2, Temp
NIBP, Spo2, Temp, Co2
* Two measurements mode:Spot, Monitoring. In monitoring mode, can continuously record 48 hours of measurement data. In spot mode, 100 users ID, each user can store 200 sets data.
* Data storage capabilities, support for historical data view and trend chart back to see.
* Support audio and visual alarm, support to set alarm upper and lower limit values.
* Lithium battery power supply.
Technical Data |
|
Display |
4 inch TFT, Resolution: 320*480 |
Indicator |
Alarm indicator, Power indicator |
Trace |
1 plethysmogram waveform, ECG wave |
Alarm |
Probe off, low power |
Modes |
Visual and Audio |
Application |
Neonatal, pediatric and adult patients |
Monitor size and weight |
Size: 146mm x 67mm x 30mm, Weight : 250g |
ECG |
|
Lead |
7 lead (R, L, F, N, C1 or RA, LA, LL, RL, V1) |
Lead mode |
Ⅰ, Ⅱ, Ⅲ, aVR, aVL, aVF, V1, CAL |
Wave |
3 waves |
Gain selction |
0.25V/mV, 0.5V/mV, 1V/mV, 2V/mV |
Bandwidth
|
Diagnositic: 0.05 -100Hz; Monitor: 0.5~ 40Hz Surgery: 1 ~ 20Hz; Stronger Fiter: 5~ 20Hz |
Heart rate
|
Range: Adult: 15 – 300bpm, Neo/Ped: 15 – 350bpm ( beats/min) Accuracy: ±1% or ±1bpm, whichever is bigger Resolution: 1 bpm(beats/min) Sensitivity: > 200 uV ( peak value ) |
SpO2 |
|
Measurement range |
SpO2: 0-100%, PR: 0-254bpm, Perfusion index: 0.05%-20% |
Accuracy range |
SpO2: 70%-100%, PR: 30-254bpm, Perfusion index: 0.05%-20% |
Accuracy
|
SpO2: Adult/Pediatric: ±2bpm(70%-100%), Neonate: ±3bpm Undefined (<70%) Under motion: ±3bpm PR: Adult/Pediatric: ±3bpm, Neonate: ±3bpm Under motion: ±5bpm |
TEMP |
|
Measurements
|
Range: 25- 45 ℃, Resolution: 0.1 ℃ Accuracy: ±0.1 ℃ (Don’t include sensor error) |
NIBP |
|
Measurement mode
|
SAWAA (Self-Adaptive-Waveform-Amplitude –Adjust) algorithm and SAFD (Self-Adaptive-Fast-Deflation) algorithm |
NIBP measurement accuracy |
土3mmHg |
Pulse rate measurement accuracy |
<=2% (>= 100 BPM) or 2 beats/min (<100 BPM) |
Pulse rate range |
40 – 240 bpm |
Measurement range
|
SYS: Adult: 40 ~ 270 mmHg, Ped: 40~ 200 mmHg, Neo: 40 ~ 135 mmHg MEAN: Adult: 20 ~ 230 mmHg, Ped: 20 ~ 165 mmHg, Neo: 20 ~ 105 mmHg DIA: Adult: 10 ~210 mmHg, Ped: 10~ 150 mmHg, Neo: 10 ~ 95 mmHg |
Independent software protection pressure |
Adult: 300mmHg, Ped: 240mmHg, Neo: 150mmHg |
Independent hardware protection pressure |
Adult: 320-330mmHg, Ped: 265-275mmHg, Neo: 60-165mmHg |
Chongqing vision star is a supplier of professional medical devices, including medical laboratory equipment, surgical equipment, ultrasound machines, radiology equipment, ophthalmology equipment, dental equipment, ENT equipment, obstetrics and gynecology equipment, neonatology equipment, rehabilitation room equipment, beauty equipment, hospital furniture, medical consumables and supplies. You can find a wide range of high quality devices that made in China for hospital or clinic. In the passed 20+ years, we have exported more than 150 countries, provided effective solutions for various types of medical system, and established long term cooperation with distributors and tenders in many countries. We sincerely support every customer with best products, prices, services, and warranty. For distributors and resellers, we can label your own logo on the devices if your order reaches MOQ. We can also help you to source more products that have not been listed on our website. Contact us to get more information.