OPM9000H Bedside Patient Monitor
$0.00
OPM9000H Bedside Patient Monitor
Feature:
* 12.1 inch, 800×600 dpi, color TFT display
* Separated Alarm and beep sound seting
* Separated module:Main board+Parameter module(ECG, NIBP, SpO2)
* Display brightness adjustable
* Real time S-T segment analysis, and ARR analysis
* SpO2 Pitch Tone Variation and Drug Dose Calculation
* Parameter waveform and characters color selectable
* Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
* Standby mode for power saving and suspend monitoring
* 7-lead ECG waveforms display in phase
* Capture dynamic waveforms and history waveforms review;
* VGA output
* Built-in rechargeable lithium battery 4 hours, and battery volume checking
* Efficient resistance to interference of defibrillator and HF knife
* SD card memory and USB data output
* TCP/IP networking platform enable abundant future upgrade& CMS
* Complete and flexible mounting solution for transportation and in-patient monitoring
* Standard parameters: 5-lead ECG, SpO2, NIBP, RESP,TEMP, HR
* Optional: Touch Screen, Printer, 3/12-lead ECG,SD card, VGA output, 2/ 4-1BP, EtCO2, AG module, Masimo/Nellcor SpO2, Wall mount, Trolley
Standard parameters |
|
ECG |
|
Lead mode |
5-lead (R, L, F, N, C) |
Lead selection |
l, ll, lll, avR, avL, avF, V |
Waveform |
3 and 7 channel selectable |
Gain selection |
0.5mm/mv, 1mm/mv, 2mm/mv |
Sweep speed |
12.5mm/s, 25mm/s, 50mm/s |
Heart rate range |
Adult: 15~300bpm, Neonate/Pediatric: 15~350bpm Accuracy: +1bpm or +1%, whichever is greater, Resolution: 1bpm |
Filter |
Surgery mode: 1~20Hz, Monitor model: 0.5~40Hz, Diagnostic mode: 0.05~130Hz |
Scaling signal |
1mv, +3% |
Protection |
withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation |
Alarm range |
15~350bpm |
SPO2 |
|
Measurement range |
0~100%, Resolution: 1%, Accuracy: +2%(70-100%); 0-69% unspecified |
Alarm range |
0~100% |
Pluse Rate |
Range: 20~300bpm, Resolution: 1bpm, Error: +1bpm or +2%, whichever is greater |
RESP |
|
Method |
Thoracic impedance |
Measurement range |
Adult: 7~120rpm, Neonate/Pediatric: 7~150rpm; Resolution: 1rpm, Accuracy: +2rpm |
Apnea alarm |
YES, 10~40s |
TEMP |
|
Compatible probe |
YSI or CYF |
Measurement range |
5~50°C |
Resolution |
0.1°C |
Accuracy |
+0.1 °C |
Refreshing time |
about 1 |
Average measuring time |
<10s |
NIBP |
|
Method |
Digital Automatic oscillometric |
Operation mode |
Manual/Automatic/continuous |
Auto measurement time |
Adjustable(1~480min) |
Measurement Unit |
mmHg/Kpa selectable |
Measurement types |
Systolic, Diastolic, Mean |
Measurement tange |
Range of Systolic pressure: Adult: 40~270mmHg, Pediatric: 40~220mmHg, Neonate: 40~135mmHg Range of mean pressure: Adult: 20~235mmHg, Pediatric: 20~165mmHg, Neonate: 20~110mmHg Range of diastolic pressure: Adult: 10~215mmHg, Pediatric: 10~150mmHg, Neonate :10~100mmHg |
Over-pressure protection |
Double safety protection |
Resolution |
1 mmHg |
Alarm |
Systolic, Diastolic, Mean |
IBP (Optional) |
|
IBP Waveform |
2-Channel, Max 8 channels |
Measurement Range |
-50-350mmHg; Resolution: ImmHg; Unit: mmHg, kPa |
Accuracy |
Static: ±1mmHg or 2%, whichever is greater (exclusive of transducer) Dynamic: ±4mmHg or 4%, whichever is greater |
Sensitivity of transducer |
5 uV/V/mmHg, ±2% |
Impedance of transducer |
300- 3000 Ohm |
Transducer sites |
ART, PA, LAP, RAP, CVP, ICP, P1, P2 |
Selection of measurement range |
ART: 0— + 350mmHg PA: -10 ~+120mmHg CVP/ RAP/ LAP/ ICP: -10 —+ 40mmHg P1/ P2: -50 ~+ 360mmHg |
Measurement range |
0~99mmHg; Accuracy: +2mmHg (0~40mmHg) |
Sampling Range |
100ml/min, Sampling rate accuracy: 15% |
Respiration rate |
0~120rmp; Respiration accuracy: +2rmp (0~70rmp), +5rmp (>70rmp) |
Respiration time |
<240msec (10% to 90%) |
Delay time |
<2s |
EtCO2 (Mainstreaam CO2, Optional) |
|
Method |
Infrared |
Spectrum Range |
0.0-10% (0~76%); Resolution: 1mmHg (0.1%) Accuracy: <5%(±4.0 mmHg) or <10%(of Readings) |
Suntech(Suntech)(Optional) |
|
Technique |
Oscillometric |
Patient Applications |
Adult Pediatric, Neonate |
Systolic Range |
40-265mmHh |
Diatolic Range |
20-200mmHh |
MAP Range |
27-222mmHh |
Pulse Range |
25-300BPM |
Transducer Accuracy |
±3mHg up to full range |
Operation Conditions |
0°C to 50°C, 15% to 95% non-condensing |
RH Storage Conditions |
-20°C to 65°C, 15%to 95% non-condensing RH |
Recorder (Optional) |
Build-in, thermal array, Fixed -time record |
Plethysmogram caveform |
2 channels |
Record mode |
Manual, on alarm, time-defined |
Recording width |
50 mm |
Printing speed |
50mm/s |
Recording type |
Frozen waveform record, NIBP recall record, Trend table record, Alarm record |
Chongqing vision star is a supplier of professional medical devices, including medical laboratory equipment, surgical equipment, ultrasound machines, radiology equipment, ophthalmology equipment, dental equipment, ENT equipment, obstetrics and gynecology equipment, neonatology equipment, rehabilitation room equipment, beauty equipment, hospital furniture, medical consumables and supplies. You can find a wide range of high quality devices that made in China for hospital or clinic. In the passed 20+ years, we have exported more than 150 countries, provided effective solutions for various types of medical system, and established long term cooperation with distributors and tenders in many countries. We sincerely support every customer with best products, prices, services, and warranty. For distributors and resellers, we can label your own logo on the devices if your order reaches MOQ. We can also help you to source more products that have not been listed on our website. Contact us to get more information.