OPM9000M+ OT/ICU/NICU Patient Monitor

$0.00

Model: OPM9000M+
Quantity:

Purchase professional medical equipment for clinic, hospital, or become our distributor. Send an inquiry or contact us now.

Send Inquiry

Chat on WhatsApp: +8613618377608

OPM9000M+ OT/ICU/NICU Patient Monitor

Feature:

* Separated para board: ECG, NIBP, SpO2 board;

* Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob.

* Real time S-T segment analysis, and ARR analysis;

* SpO2 Pitch Tone Variation and Drug Dose Calculation;

* Parameter waveform and characters color selectable

* Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic

* Standby mode for Energy saving and suspend monitoring;

* 7-lead ECG waveforms display in phase;

* Capture dynamic waveforms;

* Built-in rechargeable lithium battery, and battery volume checking,

* AC power checking

* Efficient resistance to interference of defibrillator and HF knife;

* SpO2 technology, VS NELLCOR accuracy;

* Networking capacity and TCP/IP networking platform enable abundant future upgrade

* Time delay switch-off function keep the monitor data restart monitor;

* Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.

* Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP, 2-SpO2, Nellcor/Masimo SpO2, BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO

Performance Data

 

Display

15” color TFT, Rolling and refreshing waveform display

Resolution

800×600

Multi display selectable

Large-font display, Trend coexist display, OxyCRG dynamic view display, Bed-to-bed view display

Trace

 

9 waveforms(7 ECG, 1 SPO2 and 1 RESP)

Sweep speed: 12.5mm/s, 25mm/s, 50mm/s

Indicator

 

Power/battery indicator light

QRS beep and alarm sound

Battery

Rechargeable lead acid cell, 12v/4AH

Max. 24 hour for charging, 4 hours for continue working

Trend

 

Parameter graphic and tabular trends:

5 s/piece, 8 hours;

1 min/piece, 168 hours(24 hour × 7 days)

5 min/piece,1000 hours.

Storage

NIBP: 1000 groups, Alarm: 200 groups, SD card external storage

Full disclosure waveforms

3600S

Alarm

User-adjustable High, Medium and Low limits 3-level

Audible and visual alarm

Networking

Connected to central monitoring system, TCP/IP netting platform

Recorder   

Build-in, thermal array

Plethysmogram caveform

2 channels

Record mode

Manual, on alarm, time-defined

Recording width

50mm

Printing speed

50mm/s

Recording type

Frozen waveform record, NIBP recall record, Trend table record, Alarm record, Fixed -time record

Parameter

 

ECG

 

Lead mode

5 –lead(R,L,F,N,C)

Lead selection

I, II, III, avR, avL, avF, V

Waveform

3 and 7 channel selectable

Gain selection

0.5mm/mv, 1mm/mv, 2mm/mv

Sweep speed

12.5mm/s, 25mm/s, 50mm/s

Heart rate

Range: Adult: 15~300bpm, Neonate/pediatric: 15~350bpm

Accuracy: +1bpm or +1%, whichever is greater, Resolution: 1bpm

Filter

Surgery mode: 1~20Hz, Monitor model: 0.5~40Hz, Diagnostic mode: 0.05~130Hz

Scaling signal

1mv, +3%

Protection

withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

Alarm range

15~350bpm

S-T segment detection

Measurement range: 2.0mV~+2.0mV                         

Alarm Range: -2.0mV~ +2.0mV

Accuracy: -0.8mV ~+0.8Mv, Error: +0.02Mv

Arrhythmia analysis

YES

SPO2

 

Measurement range

0~100%, Resolution: 1%, Accuracy: +2%(70-100%); 0-69%unspecified

Alarm range

0~100%

Pluse Rate

Range: 20~300bpm, Resolution:  1bpm

Error: +1bpm or +2%, whichever is greater

NIBP

 

Method

Digital Automatic oscillometric

 Operation mode

Manual/Automatic/continuous

Auto measurement time

Adjustable (1~480 min)

Measurement Unit

 mmHg/Kpa selectable

Measurement types

Systolic, Diastolic, Mean  

Measurement tange

 

Range of Systolic pressure:    

Adult: 40~270mmHg, Pediatric: 40~220mmHg, Neonate: 40~135mmHg

Range of mean pressure:      

Adult: 20~235mmHg, Pediatric: 20~165mmHg, Neonate: 20~110mmHg

Range of diastolic pressure:  

Adult: 10~215mmHg, Pediatric: 10~150mmHg, Neonate :10~100mmHg

Over-pressure protection

Double safety protection                

Resolution

1 mmHg

Alarm

Systolic.Diastolic,Mean

RESPIRATION

 

Method

Thoracic impedance

Measurement range

Adult: 7~120rpm, Neonate/Pediatric: 7~150rpm; Resolution: 1rpm, Accuracy: +2rpm

Apnea alarm

 YES, 10~40s

TEMPERATURE

 

Compatible probe

YSI or CYF

Measurement

Range: 5~50℃, Resolution: 0.1℃, Accuracy: +0.1℃

Refreshing time

about 1

Average measuring time

<10s

FHR

 

Transducer

Multi-crystal, Pulsed Doppler

Measurement range

50~210 BPM

Working frequency

1 MHz

Strength 

<5mW/cm2

Signal processing

Special DSP system and modern recognization

Resolution

1BPM

Accuracy  

±1BPM

Alarm Range

High: 160, 170, 180, 190 BPM; Low: 100, 110, 120 BPM

FM

Manual button marking, automatic FM identifying function

TOCO Measuring

 

Transducer

External pressure transducer

Measurement range

0~100 units

Resolution

1rpm

Accuracy

 ±2 rpm

IBP

 

Channel

2 channels

Range

-50-300mmHg, Resolution: 1mmHg, Accuracy: ±4mmHg(±4%), Unit: mmHg, Kpa

Converter Sensitivity

5mV/V/mmHg

Transducer sites

ART/PA/CVP/LAP/RAP/ICP

EtCO2( Sidertream CO2)

 

Measurement range

 0~99mmHg, Accuracy:  +2mmHg (0~40mmHg)

Sampling Range 

 100ml/min, Sampling rate accuracy:  15%

Respiration rate  

 0~120rmp, Respiration accuracy:  +2rmp (0~70rmp) +5rmp (>70rmp)

Respiration time   

<240msec (10% to 90%)

 Delay time

<2s

EtCO2 (mainstreaam CO2)

 

Method

Infrared Spectrum

Range

0.0-10% (0~76%), Resolution: 1mmHg (0.1%)

Accuracy

<5%(±4.0 mmHg) or <10%(of Readings) 

Others

 

 Safety        

Safety level: Class I, type CF

Dimension and Weight

Dimension: 28*42*48cm; G.W. : <6.5 kg

Operation Environment

 

Temperature

Working: 0~+40℃; Transportation and storage: –20~+60℃

Humidity

Working: ≤ 85%, Transportation and storage: ≤ 93%

Power

AC 100-240, 50/60Hz

Accessories supplies

 

(1) 5 lead ECG cable  (2) 1 Spo2 probes  

(3) 1 NIBP probe  (4) 1 temp probe

(5) 1 ground connecting liner  (6) Chest electrode (10pcs/set)

Patient range

Neonate, pediatric, and adult patients

 

Chongqing vision star is a supplier of professional medical devices, including medical laboratory equipment, surgical equipment, ultrasound machines, radiology equipment, ophthalmology equipment, dental equipment, ENT equipment, obstetrics and gynecology equipment, neonatology equipment, rehabilitation room equipment, beauty equipment, hospital furniture, medical consumables and supplies. You can find a wide range of high quality devices that made in China for hospital or clinic. In the passed 20+ years, we have exported more than 150 countries, provided effective solutions for various types of medical system, and established long term cooperation with distributors and tenders in many countries. We sincerely support every customer with best products, prices, services, and warranty. For distributors and resellers, we can label your own logo on the devices if your order reaches MOQ. We can also help you to source more products that have not been listed on our website. Contact us to get more information.