OVM7000 Vital Signs Monitor
$0.00
OVM7000 Vital Signs Monitor
Feature:
* 7″ high resolution color TFT display
* Rolling and Refreshing waveform display
* Standard 5 parameters: ECG,RESP, NIBP, SPO2, 1-TEMP
* Multi-display:standard, large font, trend coexis, OxyCRG dynamic
* Up to 4 hours working capacity of built-in rechargeable battery
* 5 Sepatated PCB board: main board, power, ECG, NIBP, SpO2
* Optional: Masimo/Nellcor SpO2, Suntech NIBP, EtCO2, C.O., BIS
Parameters |
|
NIBP |
|
Method |
Digital Automatic oscillometric |
Operation mode |
Manual/Automatic/continuous |
Auto measurement time |
Adjustable (1~480 min) |
Measurement Unit |
mmHg/Kpa selectable |
Measurement types |
Systolic, Diastolic, Mean |
Measurement tange |
Range of Systolic pressure: Adult: 40~270mmHg, Pediatric: 40~220mmHg, Neonate: 40~135mmHg Range of mean pressure: Adult: 20~235mmHg, Pediatric: 20~165 mmHg, Neonate: 20~110mmHg Range of diastolic pressure: Adult: 10~215mmHg, Pediatric: 10~150mmHg, Neonate :10~100mmHg |
Over-pressure protection |
Double safety protection |
Resolution |
1 mmHg |
SPO2 |
|
Measurement range |
0~100%; Resolution: 1%; Accuracy: +2%(70-100%), 0~69% unspecified |
Alarm range |
0~100% |
Pluse Rate |
Range: 20~300bpm, Resolution: 1bpm, Error: +1bpm or +2%, whichever is greater |
RESP |
|
Method |
Thoracic impedance |
Measurement range |
Adult: 7~120rpm, Neonate/Pediatric:7~150rpm; Resolution: 1rpm; Accuracy: +2rpm |
Apnea alarm |
YES, 10~40s |
TEMP |
|
Compatible probe |
YSI or CYF |
Measurement range: |
5~50°C; Resolution: 0, 1 X 3; Accuracy: +0.1 °C |
Refreshing time |
about 1 |
Average measuring time |
<10s |
ECG |
|
Lead mode |
5-lead(R, L, F, N, C) |
Lead selection |
l, ll, lll, avR, avL, avF, V |
Waveform |
3 and 7 channel selectable |
Gain selection |
0.5mm/mv, 1mm/mv, 2mm/mv |
Sweep speed |
12.5mm/s, 25mm/s, 50mm/s |
Heart rate range |
Adult: 15~300bpm; Neonate/pediatric: 15~350bpm Accuracy: +1bpm or +1%, whichever is greater; Resolution: 1bpm |
Filter |
Surgery mode: 1~20Hz, Monitor model: 0.5~40Hz, Diagnostic mode: 0.05~130Hz |
Scaling signal |
1mv, +3% |
Protection
|
withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation |
Alarm range |
15~350bpm |
S-T segment detection |
Measurement range: 2.0mV~+2.0mV; Alarm Range: -2.0mV~ +2.0mV Accuracy: -0.8mV ~+0.8Mv; Error: +0.02Mv |
Arrhythmia analysis |
YES |
IBP |
|
Channel |
2 channels |
Range |
-50-300mmHg; Resolution: 1mmHg; Accuracy: ±4mmHg (±4%) |
Unit |
mmHg, Kpa |
Converter Sensitivity |
SmV/V/mmHg |
Transducer sites |
ART/PA/CVP/LAP/RAP/ICP |
EtCO2 |
|
Measurement range |
0~99mmHg; Accuracy: +2mmHg (0~40mmHg) |
Sampling Range |
100ml/min, Sampling rate accuracy: 15% |
Respiration rate |
0~120rmp; Respiration accuracy: +2rmp (0~70rmp)+5rmp (>70rmp) |
Respiration time |
<240msec (10% to 90%) |
Delay time |
<2s |
Recorder |
Build-in, thermal array |
Piethysmogram caveform |
2 channels |
Record mode |
Manual, on alarm, time-defined |
Recording width |
50 mm |
Printing speed |
50 mm/s |
Recording type |
Frozen waveform record |
|
Chongqing vision star is a supplier of professional medical devices, including medical laboratory equipment, surgical equipment, ultrasound machines, radiology equipment, ophthalmology equipment, dental equipment, ENT equipment, obstetrics and gynecology equipment, neonatology equipment, rehabilitation room equipment, beauty equipment, hospital furniture, medical consumables and supplies. You can find a wide range of high quality devices that made in China for hospital or clinic. In the passed 20+ years, we have exported more than 150 countries, provided effective solutions for various types of medical system, and established long term cooperation with distributors and tenders in many countries. We sincerely support every customer with best products, prices, services, and warranty. For distributors and resellers, we can label your own logo on the devices if your order reaches MOQ. We can also help you to source more products that have not been listed on our website. Contact us to get more information.