Description
VCA12JA+ Veterinary Monitor
Feature:
- * Professional design for vet: Cats (Small), Dogs (Middle), Horses (Large)
- * 12″ color TFT display, high resolution: 800x600dpi
- * Standard 5-para: ECG, NIBP, TEMP, RESP, SPO2(Pr)
- * Color: Grey; Light blue
- * Special NIBP board for vet, alarm range, and software
- * Special accessories for vet:
- 3/5 lead ECG cable with vet limbs clip
- SpO2 sensor with tongue and ear clip
- NIBP cuff (cuff 1#, 2#, 3#, 4#, 5#)
- Rectum TEMP sensor
- * Full touch-screen enables intuitive operation +navigation knob
- * Sp02 Pitch Tone Variation
- * Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
- * Standby mode for Energy saving and suspend monitoring
- * Screen brightness adjustable
- * Capture dynamic waveforms
- * Built-in rechargeable lithium battery, and battery volume checking
- * AC power checking
- * Time delay switch-off function keeps the monitor data
- * Complete and flexible mounting solution for transportation
- * Optional/Comments: Touch screen, Printer, EtCO2, 2-IBP, NIBP, SpO2, AG(Multi-gas), Trolley/Wall mount
- * Package: 1PC/CTN: 36*20*40CM, G.W: 5.5KGS, 2PCS/CTN: 45*38*43CM, G.W: 11.10KGS
Technical Data |
|
ECG |
Lead selection: Standard 5 leads: I, II, III, AVR, AVL, AVF, V ECG amplification width: 0.05Hz-100 Hz S-T section monitoring: -2.0mV~2.0mV Electrode shedding indication: Visual, audible and electric indicate Scanning speed: 6.25, 12.5, 25, 50mm/SEC Gain selection: x1/2, x1, x2, x4 ECG calibration: 1mV+5% Protection Withstand 4000VAC/50Hz voltage isolation Alarm: The upper and lower limit of alarm value can be set, automatic memory, and alarm review ECG cable: Standard: Animal specific 3-lead ECG cable |
Heart Rate |
Detection range of heart rate: 0-350bpm Resolution: 1bpm Accuracy: ±1% |
SpO2 |
Display: Blood oxygen value, perfusion index, pulse histogram, waveform, pulse value SpO2 Range: 0%-100% for large animals or small animals Resolution: 1% Accuracy: +2%(Undefined below 70%) Pulse range: 0-300bpm Pulse accuracy: ±1bpm Standard sensors: Special probe for animal tongue and ear Alarm value: The upper and lower limit of alarm value can be set, automatic memory |
Pulse Rate |
Measurement range: 0~350 Alarm range: Upper limit: 80 to 350; Lower limit: 20 to 150 |
NIBP |
Measurement method: Digital automatic oscillometric Measurement parameters: Systolic pressure, Diastolic pressure, Mean pressure, Pulse rate Working mode: Manual, automatic, and continuous measurement Unit: mmHg/KPa Optional Interval time of automatic measurement: 0~250min adjustable Overvoltage protection: Hardware and software protection Measurement range: Large animals: 10mmHg~ 300mmHg Small animals: 10mmHg~200mmHg Cuff pressure range: 0~320 mmHg Standard cuff: 1#, 2#, 3#, 4#, 5# total 5PCS Aeration time: Less than 6 seconds Test vent time: Less than 15 seconds |
TEMP |
Measurement range: 0°C~50°C Resolution: 0.1°C Accuracy: ±0.1°C Standard probe: Esophagus/ rectum temp probe Alarm: Upper and lower limit value can be set, automatic memory |
RESP |
Measurement method: Thoracic impedance Respiration rate (RR): A). Measurement range: 0-120bpm B). Measurement accuracy: +1bpm or 5%bp Alarm: Upper and lower limit value can be set, automatic memory |
2-IBP(Optional)
|
Number of channels: 2 Pressure sensor nominal sensitivity: 5uV/N/mmHg, error +2% Pressure sensor input impedance, output impedance: 3000 ~30002 Static pressure measurement range: -50~+300mmHg (Up to 350 mmHg) Static pressure measurement error: ±1mmHg or ±1%, greater (Not including probe); ±4mmHg or ±4%, greater (Including probe) Dynamic pressure measurement range: -50~+300mmHg Dynamic pressure measurement error: ±4mmHg or ±4% of reading (greater) Vessel types: ART, PA/ CVP/ RAP/ LAP/ ICP Scope of stress test: ART: 0~300mmHg AP/RAP/LAP/ICP: -50~120mmHg Resolution: 1mmHg |
EtCO2(Optional) |
Sampling Type: Mainstream/Side stream Sampling Velocity: Range: 50-150 ml/min Accuracy: +20% Default value: 75ml/min Measurement principle: Non-spectral infrared, double channel, no moving parts(degassing pump) |