Description
VCA200CV Handheld Veterinary Vital Sign Monitor
- * ECG: 3/5 Leads, 3 waves
- * Accurate measurement in 0.05% Low perfusionIndex,the word leading production in the movement environment
- * Provide the parameter of PI( Perfusion Index05%-20%)
- * Accurate measurement in all kind of extreme environment measurement such as Big animal andSmall animal
- * NIBP adopt SAWAA(Self. Adaptive-Wave-form-Amplitude-Adjust) algorithm and SAFD( Self-Adaptive-Fast-Dflation) algorithm
- * Easy operation by 4″ color TFT
- * Up to 100 users ID switch
- * Multiple vital signs measurement parametersfor collocation optional
- * 3/5 Leads ECG, NIBP, Spo2, Temp
- * NIBP, Spo2, Temp, Co2
- * Two measurements mode: Spot, Monitoring
- * Data storage capabilities, support for historical data view and trend chart back to see
- In monitoring mode, can continuously record 48 hours of measurement data
- In spot mode, 100 users ID, each user can store 200 sets data
- * Support audio and visual alarm, support to set alarm upper and lower limit values
- * Lithium ion battery power supply
Technical Data |
|
Display |
4” TFT |
Resolution |
320*480 |
Indicator |
Alarm indicator, Power indicator |
Trace |
1 plethysmogram waveform, ECG wave |
Alarm |
Probe off, low power |
Modes |
Visual and Audio |
Application |
Big animal and Small animal |
Power Type |
Lithium ion battery Operation time: 8 hours for normal operation |
Temperature |
Operating: 0°C-45°C Storage/ Transportation: -20°C~65°C |
Humidity |
Operating: 15% to 90% noncondensing Storage: 0% to 95% noncondensing |
Altitude |
Operating Altitude: Up to 5000 meters |
Dimension |
146mm*67mm*30mm |
Weight |
250g |
ECG |
|
Lead |
3 or 5 lead(R, L, F, N, C1 or RA, LA, LL, RL, V1) |
Lead mode |
I, II, III, aVR, aVL, aVF, V1, CAL |
Wave |
3 waves |
Gain selection |
0.25V/mV, 0.5V/mV, 1V/mV, 2V/mV |
Heart Rate |
Heart Rate Big animal Small animal Range 15~300bpm 15~350bpm Accuracy ±1% or ±1bpm Bigger Resolution1 bpm Sensitivity> 200 uV (peak to peak) |
Bandwidth
|
Diagnositic: 0.05 ~100 Hz Monitor: 0.5~ 40Hz Surgery: 1-20Hz Stronger Filter: 5~ 20Hz |
Oxygen Saturation (%SpO2) |
|
Measure range
|
Measure range Accuracy range SpO2 0-100% 70-100% PR 0-254bpm 30-254bpm Perfusion Index 0.05%-20% |
Measurement acuracy |
SpO2 PR Adult incuding pdisaric) ±2bpm(70%-100%) ±3bpm Neonute ±3bpm not defined(<70%) ±3bpm On motion condition ±3bpm ±5bpm |
Temperature |
|
Measurement range |
25- 45°C |
Resolution |
0.1°C |
Accuracy |
0.1°C |
NIBP |
|
The wider NIBP measurement range |
Big animal Small animal SYS 40-270mmHg 40-200mmHg MEAN 20~ 230mmHg 20~-165mmHg DIA 10-210mmHg 10~150mmHg Pulse rate range: 40~240bpm |
NIBP measurement accuracy |
±3mmHg |
Pulse rate measurement accuracy |
<=2% (>=100 BPM) or 2 beats/min (<100BPM) |
Indpendent software protection presure |
300mmHg(Big animal) 300mmHg(Small animal) |
Independent hardware protection presure |
320-330mmHg(Big animal) 320-330mmHg(Small animal) |