Description
VET-12N+ Veterinary Monitor
Feature:
* Parameters: Standard 5 Para: ECG, SpO2(PR), NIBP, TEMP, RESP
* Screen: 12 inch TFT Screen, 800×600 dpi
* Color: Grey, White
* Optional parameter: ETCO2, 2-IBP, Printer, Touchscreen, 3/12-lead ECG, Multi-gas(AG), BIS, Masimo/Nellcor SpO2, Suntech NIBP, Wall Mount, Trolley
Standard parameter |
|
ECG |
|
Lead mode: |
5 –lead(R, L, F, N, C) (3/12 lead ECG for optional) |
Lead selection: |
I, II, III, avR, avL, avF, V |
Waveform: |
3 and 7 channel selectable |
Gain selection: |
0.5mm/mv,1mm/mv,2mm/mv |
Sweep speed: |
6.25mm/s;12.5mm/s;25mm/s;50mm/s |
Heart rate range |
Adult: 15~300bpm; Neonate/pediatric: 15~350bpm |
Filter |
Surgery mode: 1~20Hz, Monitor model: 0.5~40Hz, Diagnostic mode: 0.05~130Hz |
Scaling signal |
1mv, +3% |
Protection |
withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation |
Alarm range |
15~350bpm |
S-T segment detection |
Measurement range: 2.0mV~+2.0mV, Alarm Range: -2.0mV~ +2.0mV |
Arrhythmia analysis |
YES |
SPO2 |
|
Measurement range: |
0~100% |
Wave speed |
12.5mm/s; 25mm/s |
Resolution |
1% |
Accuracy |
+2% (70-100%); 0-69% unspecified |
Alarm range |
0~100%, Lower perfusion situation |
Pulse Rate(PR) |
|
Range |
20~300bpm |
Resolution |
1bpm |
Error |
+1bpm or +2%, whichever is greater |
NIBP |
|
Method |
Digital Automatic oscillometric |
Operation mode |
Manual/Automatic |
Auto measurement time |
Adjustable (1~720min) |
Measurement Unit |
mmHg/Kpa selectable |
Measurement types |
Systolic, Diastolic, Mean |
Measurement Range |
Range of Systolic pressure: Adult: 40~270mmHg, Pediatric: 40~220mmHg, Neonate: 40~135mmHg Adult: 20~235mmHg, Pediatric: 20~165mmHg, Neonate: 20~110mmHg Adult: 10~215mmHg, Pediatric: 10~150mmHg, Neonate: 10~100mmHg |
Over-pressure protection |
Double safety protection |
Resolution |
1 mmHg |
Alarm |
Systolic, Diastolic, and Mean |
RESPIRATION |
|
Method |
RA-LL impedance |
Measurement range |
Adult: 7~120rpm; Neonate/Pediatric: 7~150rpm; Resolution: 1rpm; Accuracy: +2rpm |
Apnea alarm |
YES, 10~40s |
TEMPERATURE |
|
Compatible probe |
YSI or CYF |
Measurement range |
5~50℃, Resolution: 0.1℃, Accuracy: +0.1℃ |
Refreshing time |
about 1 |
Average measuring time |
<10s |
Others |
|
Safety |
Safety level: Class I, type CF |
Dimension and Weight |
Dimension: 28*42*48cm, G.W: <6.5KS |
Operation Environment |
|
Temperature: |
Working 0~+40℃ |
Transportation and storage |
–20~+60℃ |
Humidity |
working≤85%, Transportation and storage≤93% |
Power: |
AC 100-240, 50/60Hz |