VET-12N+ Veterinary Monitor

$0.00

SKU: VET-12N+ Category:

Description

VET-12N+ Veterinary Monitor

Feature:

* Parameters: Standard 5 Para: ECG, SpO2(PR), NIBP, TEMP, RESP

* Screen: 12 inch TFT Screen, 800×600 dpi

* Color: Grey, White

* Optional parameter: ETCO2, 2-IBP, Printer, Touchscreen, 3/12-lead ECG, Multi-gas(AG), BIS, Masimo/Nellcor SpO2, Suntech NIBP, Wall Mount, Trolley

Standard parameter

 

ECG

 

Lead mode:

5 –lead(R, L, F, N, C) (3/12 lead ECG for optional)

Lead selection:

I, II, III, avR, avL, avF, V

Waveform:

3 and 7 channel selectable

Gain selection:

0.5mm/mv,1mm/mv,2mm/mv

Sweep speed:

6.25mm/s;12.5mm/s;25mm/s;50mm/s

Heart rate range

Adult: 15~300bpm; Neonate/pediatric: 15~350bpm
Accuracy: +1bpm or +1%, which is greater, Resolution: 1bpm

Filter

Surgery mode: 1~20Hz, Monitor model: 0.5~40Hz, Diagnostic mode: 0.05~130Hz

Scaling signal

1mv, +3%

Protection

withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation

Alarm range

15~350bpm

S-T segment detection

Measurement range: 2.0mV~+2.0mV, Alarm Range: -2.0mV~ +2.0mV
Accuracy: -0.8mV ~+0.8Mv, Error: +0.02Mv

Arrhythmia analysis

YES

SPO2

 

Measurement range:

0~100%

Wave speed

12.5mm/s; 25mm/s

Resolution

1%

Accuracy

+2% (70-100%); 0-69% unspecified

Alarm range

0~100%, Lower perfusion situation

Pulse Rate(PR)

 

Range

20~300bpm

Resolution

1bpm

Error

+1bpm or +2%, whichever is greater

NIBP

 

Method

Digital Automatic oscillometric

Operation mode

Manual/Automatic

Auto measurement time

Adjustable (1~720min)
(1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480, 720min)

Measurement Unit

 mmHg/Kpa selectable

Measurement types

Systolic, Diastolic, Mean

 Measurement Range

Range of Systolic pressure:

Adult: 40~270mmHg, Pediatric: 40~220mmHg, Neonate: 40~135mmHg
Range of mean pressure:

Adult: 20~235mmHg, Pediatric: 20~165mmHg, Neonate: 20~110mmHg
Range of diastolic pressure:

Adult: 10~215mmHg, Pediatric: 10~150mmHg, Neonate: 10~100mmHg

Over-pressure protection

Double safety protection

Resolution

1 mmHg

Alarm

Systolic, Diastolic, and Mean

RESPIRATION

 

Method

RA-LL impedance

Measurement range

Adult: 7~120rpm; Neonate/Pediatric: 7~150rpm;

Resolution: 1rpm; Accuracy: +2rpm

Apnea alarm

YES, 10~40s

TEMPERATURE

 

Compatible probe

YSI or CYF

Measurement range

5~50℃, Resolution: 0.1℃, Accuracy: +0.1℃

Refreshing time

about 1

Average measuring time

<10s

Others

 

Safety

Safety level: Class I, type CF

Dimension and Weight

Dimension: 28*42*48cm, G.W: <6.5KS

Operation Environment

 

Temperature:

Working 0~+40℃

Transportation and storage

–20~+60℃

Humidity

 working≤85%, Transportation and storage≤93%

Power:

AC 100-240, 50/60Hz