VP50C Canine Progesterone Analyzer

Feature:

  • * Test the situation of estrus and ovulation of female canine
  • * Master the breeding time of female canine
  • * Test the situation of estrus by analysis of date.
  • * Master the optimal breeding time by accurately testing the situation of ovulation of female canine.
  •  
  • * Premature birth threat in pregnancy by rapid test
  • * Auxiliary prediction of cesarean
  • * Predict in advance whether there is a harbinger of premature birth for the female canine.
  •  
  • * Easy to operate,get the result in 15 minutes
  • * The test report can be printed
  • * Click “test” button,the result will be showed after timing is over.
  •  

Instruction:

  • Operation Precautions
  •  
  • After venous blood extraction, if the serum is not well separated within 15 minutes, it can be separated for several more minutes. Hemolysis does not affect the value.
  • The centrifuged serum is recommended for immediate detection.
  • The pipette gun has two stages. When extracting serum, it is directly pressed to the first stage instead of the bottom. Drop the serum directly to the bottom of the reagent card. This test is a quantitative test for 80ul.
  • Place the reagent card horizontally, hold the pipette gun vertically, and drop the serum into the round hole of the reagent card. When the serum is about to flow to the detection area of the long slot, insert the equipment.
  • Insert the reagent card into the card slot until there is resistance.
  • The result will be displayed automatically after the detection is completed.
  • Ambient temperature and serum temperature will affect the reagent and test results. The whole operation must be carried out at a constant temperature between 22℃ and 30℃, and the reagent card stored in low temperature should be kept at a constant temperature 30 minutes in advance before use.
  • The corresponding of the item and the test paper. The value will be affected if the item is not matched.
  • When the machine is not in use, keep it off.
  • Keep the device hygienic in case of afecting the test effect.
  • The test stripe is a disposable consumable and cannot be reused.
  • The serum is dripped into the round hole,if dose not flow into the test zone within 30 seconds, the strip is forbidden to be used.

Technical Data

 

Storage result

500

Test channel

Single channel

Test duration

15min/ time

Power supply

100-240V AC, 50/60Hz, 12V DC

Working environment

Temperature: 5°C, humidity: 10-70%

Size

210*175*75mm

Weight

1kg

 

Numerical Criteria Reference

> 0. 1

Proestrus

0.2-1.9

Proestrus. Analyze again after 72 hours.

2.0-3.9

Proestrus. Analyze again after 48 hours.

4.0-5.9

Proestrus. Analyze again after 36 hours.

6.0-7.5

Proestrus. Analyze again after 24 hours.

7.6-8.5

Proestrus. Inseminate after 24 hours!

8.6-9.9

Proestrus. Inseminate after 12 hours!

10.0-15.0

Estrus. Inseminate right away. The second insemination should be operated after 24 hours.

15.1-20.00

Estrus Inseminate right away. The second insemination should be operated after 12 hours.

20.1-25.0

The end of Estrus. Estrus Inseminate right away. No second insemination.

25.1-30.0

Diestrus. Low pregnancy rate.

30.1- > 50

Between diestrus and anestrus. Missed the insemination time.

 

Problem

Solution

Progesterone mainframe is inaccurate

Project data does not match

Check whether the reagent card date matches the item first

 (The date of the orange item should be checked at the standard test and batch number, and the date of the blue item should be checked at the current item on the upper left of the test.)

Ambient temperature

Reagent cards stored in low temperature should be kept at a constant temperature (22℃-30℃) 30 minutes in advance before use. The temperature difference of more than 10 degrees from the standard temperature may cause different degrees of running high.

Progesterone didn’t go up. It went down

(1) False estrus, the data will never come, will be lower and lower, completely restore the non-estrus state, two estrus after a month.

(2) Ovulation delay, follicle development retardation, detection of late can slowly rise, mating time may be extended to 20-40 days range

(3) Hormonal confusion, always stay in the interval of 5 values below, estrus state looming, serious hormonal disorders, more frequent in summer. It is suggested to optimize the breeding conditions, adjust the diet, and observe and monitor the later period.

All of a sudden, progesterone is way up

Improper use by customers or centralized ovulation

(1) The use of 80 microliter pipette gun is not strictly implemented, and the value caused by a little more drops is high.

(2) The sudden rapid doubling of the rise, on behalf of concentrated ovulation, even if it reaches more than 60 do not worry, as soon as possible can be mated. However, if the data increase more than three times in 24 hours, the first possibility takes precedence.

Estrus shows < 0.3 (orange < 0.5)

In summer, multiple ovulation apparatus lasts for several days, not more than 200, progesterone is not more than 1, but there is estrus performance, it is recommended to continue monitoring, due to the hot weather caused by the slow development of follicles, the problem of prolonged physiological cycle, sometimes occur. At the same time, male dogs will also have poor sperm quality in summer, so outdoor breeding in summer pregnancy rate will be reduced.

The contrast between the two machines is large

Numerical deviation is caused by different system items

First make sure there is no confusion between the item and the test paper. The same serum was then used for comparison.

Then it is necessary to determine whether the reference synchronicity of the two systems is within a range of recommended mating reference values. The overall data design of some old systems is too high. If a special environment reference deviation is not expected, you can contact the after-sales service for customized system control services.

If two machine project test paper match, you can choose to test the machine or customize the system upgrade service for customers.

What is the best value for mating? Can we just not change the numbers

We have been following the uniform optimal mating values range.

However, in this process, there are still regional differences of dogs in different breeding environments (reactions of a few areas) and differences of responses of test paper in different environments, resulting in biased data.

The latest mating value of the system is 30, and the early mating value of the small and the old is 26-30.

Factors affecting progesterone levels

Different dog breeds, different body types, different individuals, different living environments and other factors can cause a certain degree of deviation, but not particularly large

Factors that affect the value for the customer:

(1) The operating environment, large and sudden changes in temperature and humidity will affect the data

(2) Breeding environment, sudden changes in the living environment of dogs will cause abnormal progesterone value and physiological cycle in the cycle.

(3) System matching, not corresponding test paper and system will have instability.

What should be 30 days after mating? Can you tell if you’re pregnant? When to have a C-section

The value at 30 days of mating should be greater than the value at the time of mating. If you want to monitor whether the mating is normal, it should be tested within 7 days after mating. If the progesterone value decreases, it should be supplemented in time.

A rapid decrease in the data after mating indicates a high risk of pregnancy, while normal data can only represent the formation of pregnancy conditions, but does not represent 100% pregnancy.

When does progesterone eat best?

Progesterone plays a key role in follicular development through embryonic growth. If the estrus period does not rise for a long time, the appearance, microscope and ovulation apparatus are in good condition, supplement, and then timely mating after data arrival.

In addition, it is not recommended to blindly take large doses or injections. Because progesterone has the effect of relaxing the uterus, if excessive intake during pregnancy, will cause uterine contraction performance decreased, causing dystoia.

If the data is not long or even slightly decreased within 7 days after mating, it shall be supplemented appropriately.

Empty card read value

Cline is too low

This is a system setup problem, as long as the serum card will be added to the normal value, you can use it normally.

Normal card display invalid

1. No serum

2. The card is inserted backwards 

3. C line is too high

Please make sure whether the serum flows into the reagent card normally and whether it is inserted in the wrong direction at the same time. If there is no problem, some samples will be invalid. Consider the problem of system setting!

Data error

Electromagnetic interference

Change the operating environment

According to the Tes

Numerical 100.000

The reference range is shown as 1.000-2.000

The system is deleted.

Brush into the system

Please check the recommended reference values behind the test results. If 1.000-2.000 indicates that the test item has been deleted! Need chip brush, or remote computer write!

Chongqing vision star is a supplier of professional medical devices, including medical laboratory equipment, surgical equipment, ultrasound machines, radiology equipment, ophthalmology equipment, dental equipment, ENT equipment, obstetrics and gynecology equipment, neonatology equipment, rehabilitation room equipment, beauty equipment, hospital furniture, medical consumables and supplies. You can find a wide range of high quality devices that made in China for hospital or clinic. In the passed 20+ years, we have exported more than 150 countries, provided effective solutions for various types of medical system, and established long term cooperation with distributors and tenders in many countries. We sincerely support every customer with best products, prices, services, and warranty. For distributors and resellers, we can label your own logo on the devices if your order reaches MOQ. We can also help you to source more products that have not been listed on our website. Contact us to get more information.