VXR5KWA Portable Digital Radiography System
$0.00
VXR5KWA Portable Digital Radiography System
Features:
- * LCD touch screen.
- * Easy positioning changes enable sequential exposures of the chest and abdomen to be acquired quickly and easily for efficient technologist workflow.
- * Four swiveling wheel casters allow precise, easy positioning and travel in any direction, and the ability to spin the system in place in tight spaces.
- * The articulating control panel allows rotation and height adjustment for instant image confirmation from any angle.
- * The small lightweight design and extended reach of the tube head allows one-hand operation for easy exam positioning.
Technical Parameters |
|||
Model |
VXR5KWA |
VXR8KWB |
VXR125C |
Power Output |
5kW |
8kW |
12.5KW |
Current |
10-100mA |
10-125mA |
10-160mA |
Voltage |
40-125kV |
40-125KV |
40-130KV |
mAs |
0.1-200mAs |
0.1-400mAs |
0.1-630mAs |
Exposure time |
1-4000ms |
1-6300ms |
1-6300ms |
Focus Size |
1.0/2.0 |
0.6/1.2 |
0.6/1.2 |
INP-5kW-P-A Parameters |
|
Common Parameter |
|
Output Power |
5.3kW |
Rated voltage |
220VAC, ±10%, 50Hz |
Inverter frequency |
100kHz ±5% |
kV accuracy |
Full range: ±4% |
mA accuracy |
≤±(5% ) (mA>25mA, ms>5) ≤±(10% +1mA) (mA≤25mA) |
Anode speed |
Fixed anode |
Exposure Parameter |
|
Exposure KV range |
40kV-125kV, 1kV step |
Exposure mA range |
10-100mA(Adopt R’10 or R’20 standard) |
Exposure ms range |
1-4000ms (Adopt R’10 or R’20 standard) |
Exposure ms accuracy |
≤±(5% +0.2ms) |
Exposure mAs range |
0.1-200mAs (Adopt R’10 or R’20 standard) |
Exposure mAs accuracy |
≤±(5%+0.2mAs) |
Optional Parameter |
|
Optional exposure technology |
kV-mAs kV-mA-ms |
Communication Interface |
RS-232, Supports communication with PC |
Dimensions(mm) |
280*255*220(Not include collimator) 450*255*220(Include collimator) |
Weight(kg) |
17kg(Include collimator and battery) |
Tube focus |
Small focus 0.6, large focus 1.8 |
Battery Parameter |
|
Battery capacity |
6Ah |
Rated voltage/current |
22.2V/1.2A |
Exposure interval |
1.5min |
Usage environment |
Lithium battery charging temperature range: 0~40 degrees Celsius, lithium battery discharge temperature range -20~60 degrees Celsius. |
Storage environment |
* Lithium-ion batteries should be stored in a relatively cool, dry, and ventilated environment, away from fire sources and high temperatures. The battery storage temperature must be within the range of 0°C~45°C, and the humidity must be 65±20%RH. * Storage voltage and power: voltage is 22.2V~24.0V; * Long-term storage batteries(more than 3 months) must be placed in an environment with a temperature of 0-20°C and a humidity of 65±20% RH. |
Offline impressions |
Fully charged, one exposure is 200. You can expose during the charging process. This is not recommended. |
Chongqing vision star is a supplier of professional medical devices, including medical laboratory equipment, surgical equipment, ultrasound machines, radiology equipment, ophthalmology equipment, dental equipment, ENT equipment, obstetrics and gynecology equipment, neonatology equipment, rehabilitation room equipment, beauty equipment, hospital furniture, medical consumables and supplies. You can find a wide range of high quality devices that made in China for hospital or clinic. In the passed 20+ years, we have exported more than 150 countries, provided effective solutions for various types of medical system, and established long term cooperation with distributors and tenders in many countries. We sincerely support every customer with best products, prices, services, and warranty. For distributors and resellers, we can label your own logo on the devices if your order reaches MOQ. We can also help you to source more products that have not been listed on our website. Contact us to get more information.